aggame¹ÙÍø

¡°¼«¼ò¡±»ÀР¡¤ È«ÓòÖÇÁª Ø­ aggame¹ÙÍøÐ¼«¼òÁ캽ÏÂÒ»´úÐ£Ô°Íø½¨Éè×êÑлá
Ô¤Ô¼Ö±²¥
ÎÞ¸Ð×¼Èë ÈËÎïͳ¹Ü Ø­ RG-SAM+5.X ÐÂÒ»´ú¸ßУAIÈÏ֤ƽ̨Ðû²¼
Ô¤Ô¼Ö±²¥
AGGAME¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
²úÆ·
< ·µ»ØÖ÷²Ëµ¥
²úÆ·ÖÐÐÄ
²úÆ·
½â¾ö¼Æ»®
< ·µ»ØÖ÷²Ëµ¥
½â¾ö¼Æ»®ÖÐÐÄ
ÐÐÒµ
ÏàÖúͬ°é
·µ»ØÖ÷²Ëµ¥
Ñ¡ÔñÇøÓò/ÓïÑÔ
AGGAME¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
RG-S2910V2-24GT4SFP-P-L
RG-S2910V2-24GT4SFP-P-L
RG-S2910V2-24GT4SFP-P-L
RG-S2910V2-24GT4SFP-P-L
RG-S2910V2-24GT4SFP-P-L
RG-S2910V2-24GT4SFP-P-L
RG-S2910V2-24GT4SFP-P-L
RG-S2910V2-24GT4SFP-P-L
RG-S2910V2-24GT4SFP-P-L
RG-S2910V2-24GT4SFP-P-L
RG-S2910V2-24GT4SFP-P-L
AGGAME¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
AGGAME¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
AGGAME¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
AGGAME¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
AGGAME¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
AGGAME¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
AGGAME¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
AGGAME¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
AGGAME¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
AGGAME¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
AGGAME¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
¼ÓÔØÖÐ...0%
ͼƬ

24¿ÚǧÕ×Èý²ãÍø¹ÜÐͺÐʽ½ÓÈëPoE½»Á÷»ú £¬£¬£¬£¬£¬£¬£¬Ç§Õ×ÉÏÐÐ £¬£¬£¬£¬£¬£¬£¬RG-S2910V2-24GT4SFP-P-L

Ó¦ÓÃÓÚÆÕ½Ì£¨³ÇÓòÍø¡¢ÖÐСѧ£©¡¢ÉÌÒµµØ²ú¡¢Ö°½Ì¡¢ÆóÒµµÈÊг¡ £¬£¬£¬£¬£¬£¬£¬Ö÷Òª³¡¾°ÊÇ°ì¹«Íø¡¢×°±¸Íø¡¢Ô°Çø¼à¿ØµÄǧÕ×½ÓÈëµÈ

²úÆ·ÌØÕ÷£º

  • 24¸ö10/100/1000Base-T×Ô˳ӦÒÔÌ«Íø¿Ú £¬£¬£¬£¬£¬£¬£¬4¸ö×ÔÁ¦Ç§Õ×SFP¹â¿Ú
  • Ö§³ÖPoE+¹©µç £¬£¬£¬£¬£¬£¬£¬µ¥¶Ë¿Ú×î´ó¹¦ÂÊ´ï30W
  • ÌØÓеÄCPU±£»£»£»£»£»£»¤Õ½ÂÔ £¬£¬£¬£¬£¬£¬£¬×°±¸Îȹ̸߿ɿ¿ £¬£¬£¬£¬£¬£¬£¬ÍøÂçÔËÐв»ÖÐÖ¹
  • ¿ìËÙ»·Â·¼ì²â£¨RLDP£© £¬£¬£¬£¬£¬£¬£¬ÍøÂçÇå¾²¸üÁ÷ͨ
  • Ö§³ÖEEEÊÖÒÕ £¬£¬£¬£¬£¬£¬£¬×Ô¶¯µ÷Àí¶Ë¿Ú¹¦ÂÊ £¬£¬£¬£¬£¬£¬£¬½µÔëÇÒ½ÚÄÜ
  • ¶à·½·¨Íø¹Ü £¬£¬£¬£¬£¬£¬£¬×°±¸ÖÎÀíÇáËÉÒײÙ×÷
Á¬Ã¦×Éѯ

Èí¼þЭÒé

¸ß¿É¿¿ÐÔ
STP/RSTP/MSTP
RLDP/LLDP
LACP
Ó¦ÓÃЭÒé
DNS
DHCP Server
Port based VLAN¡¢MAC Based VLAN¡¢GVRP
REUP
IGMP SNOOPING
ÖÎÀíÌØÕ÷
SNMP
RMON
Syslog/Debug
NTP/SNTP
WebÖÎÀí¡¢CLI(Telnet/Console)¡¢SSH
Çå¾²ÌØÕ÷
CPP
ACL/QoS
DOS PROTECTION
¹ýÂ˲»·¨µÄMACµØµã
Ö§³Ö¹ã²¥·ç±©ÒÖÖÆ
¿ÚÁîÇå¾²

24¿ÚǧÕ×Èý²ãÍø¹ÜÐͽÓÈë½»Á÷»ú
RG-S2910V2-24GT4SFP-P-L

×ñÕÕIEEE 802.3afºÍIEEE 802.3at±ê×¼ £¬£¬£¬£¬£¬£¬£¬Ö§³ÖPoE+¹©µç £¬£¬£¬£¬£¬£¬£¬Öª×ã°²·À¼à¿Ø¡¢µç»°¾Û»áϵͳ¡¢ÎÞÏßÁýÕֵȳ£¼ûPoE¹©µçµÄÐèÇó
¿´¶Ë¿Ú
¿´Ó¦ÓÃ

ÌØÓеÄCPU±£»£»£»£»£»£»¤Õ½ÂÔ £¬£¬£¬£¬£¬£¬£¬×°±¸Îȹ̿ɿ¿ £¬£¬£¬£¬£¬£¬£¬ÍøÂçÔËÐв»ÖÐÖ¹

¾ßÓÐCPPÌØÕ÷£¨CPU Protect Policy£© £¬£¬£¬£¬£¬£¬£¬¿ØÖÆ·¢ÍùCPUµÄ±¨ÎÄÀàÐͺÍÁ÷Á¿¾Þϸ £¬£¬£¬£¬£¬£¬£¬È·±£Õý³£Ð­Ò鱨ÎĺÍÖÎÀí±¨ÎĵÄ
´¦Öóͷ£ £¬£¬£¬£¬£¬£¬£¬³ä·Ö±£»£»£»£»£»£»¤CPU²»±»²»·¨Á÷Á¿Õ¼ÓᢶñÒâ¹¥»÷ºÍ×ÊÔ´ÏûºÄ

¿ìËÙ»·Â·¼ì²â£¨RLDP£© £¬£¬£¬£¬£¬£¬£¬ÍøÂçÇå¾²¸üÁ÷ͨ

Ö§³Ö¿ìËÙÁ´Â·¼ì²âЭÒ飨RLDP£© £¬£¬£¬£¬£¬£¬£¬¿ìËÙ·¢Ã÷¶Ë¿Ú˽½ÓHubµÈ×°±¸ÐγɵĻ·Â· £¬£¬£¬£¬£¬£¬£¬²¢ÊµÊ±×÷³öÖÒÑÔ֪ͨ¡¢¹Ø±Õ¶Ë¿ÚµÈ´¦Öóͷ£
´Ó¶øÔ¤·ÀÓÉÓÚ»·Â·Ôì³ÉµÄ¹ã²¥·ç±© £¬£¬£¬£¬£¬£¬£¬°ü¹Ü×°±¸ºÍÁ´Â·Çå¾²

Ö§³ÖEEEÊÖÒÕ £¬£¬£¬£¬£¬£¬£¬×Ô¶¯µ÷Àí¶Ë¿Ú¹¦ÂÊ £¬£¬£¬£¬£¬£¬£¬½µÔëÇÒ½ÚÄÜ

Ö§³Ö¸ßЧ½ÚÄÜÒÔÌ«Íø£¨EEE£©ÊÖÒÕ £¬£¬£¬£¬£¬£¬£¬¶Ë¿ÚÁ÷Á¿½ÏСʱ £¬£¬£¬£¬£¬£¬£¬¹¦ÂÊ×Ô¶¯½µµÍ £¬£¬£¬£¬£¬£¬£¬½ÚÔ¼×°±¸Äܺ컣»£»£»£»£»¶Ë¿ÚÎÞÁ÷Á¿Ê± £¬£¬£¬£¬£¬£¬£¬×Ô¶¯½øÈëÐÝÃßģʽ £¬£¬£¬£¬£¬£¬£¬½µÔëÇÒ½ÚÄÜ

¶à·½·¨Íø¹Ü £¬£¬£¬£¬£¬£¬£¬×°±¸ÖÎÀíÇáËÉÒײÙ×÷

µ¥Ì¨×°±¸ÖÎÀí
¶ą̀װ±¸ÖÎÀí

¿É½ÓÄÉWebÖÎÀí¡¢CLI(ÏÂÁîÐнӿÚ)µÈ¶àÑù»¯µÄÍâµØ»¯ÖÎÀíºÍά»¤·½·¨ £¬£¬£¬£¬£¬£¬£¬×°±¸ÖÎÀí¼òÆÓ±ã½Ý

ÊÖÒÕ²ÎÊý

ÊÖÒÕ²ÎÊý

²ÎÊýÐÎò

²úÆ·ÐͺÅ

RG-S2910V2-24GT4SFP-L

RG-S2910V2-24GT4XS-L

RG-S2910V2-48GT4SFP-L

RG-S2910V2-48GT4XS-L

RG-S2910V2-24GT4SFP-P-L

RG-S2910V2-24GT4XS-P-L

Àο¿¶Ë¿Ú

24¸ö10/100/1000M×Ô˳Ӧµç¿Ú £¬£¬£¬£¬£¬£¬£¬4¸ö1G SFP¹â¿Ú £¬£¬£¬£¬£¬£¬£¬¹Ì»¯µ¥½»Á÷µçÔ´

 

24¸ö10/100/1000M×Ô˳Ӧµç¿Ú £¬£¬£¬£¬£¬£¬£¬4¸ö10G/1G SFP+¹â¿Ú £¬£¬£¬£¬£¬£¬£¬¹Ì»¯µ¥½»Á÷µçÔ´

48¸ö10/100/1000M×Ô˳Ӧµç¿Ú £¬£¬£¬£¬£¬£¬£¬4¸ö1G SFP¹â¿Ú £¬£¬£¬£¬£¬£¬£¬¹Ì»¯µ¥½»Á÷µçÔ´

 

48¸ö10/100/1000M×Ô˳Ӧµç¿Ú £¬£¬£¬£¬£¬£¬£¬4¸ö10G/1G SFP+¹â¿Ú £¬£¬£¬£¬£¬£¬£¬¹Ì»¯µ¥½»Á÷µçÔ´

24¸ö10/100/1000M×Ô˳Ӧµç¿Ú £¬£¬£¬£¬£¬£¬£¬4¸ö1G SFP¹â¿Ú £¬£¬£¬£¬£¬£¬£¬¹Ì»¯µ¥½»Á÷µçÔ´

 

24¸ö10/100/1000M×Ô˳Ӧµç¿Ú £¬£¬£¬£¬£¬£¬£¬4¸ö10G/1G SFP+¹â¿Ú £¬£¬£¬£¬£¬£¬£¬¹Ì»¯µ¥½»Á÷µçÔ´

 

24¸öµç¿ÚÖ§³ÖPoEºÍPoE+¹©µç£»£»£»£»£»£»Õû»ú×î´óPoE/PoE+Êä³ö¹¦ÂÊ£º370W

½»Á÷ÈÝÁ¿

336Gbps/3.36Tbps

432Gbps/4.32Tbps

336Gbps/3.36Tbps

°üת·¢ÂÊ

51Mpps/126Mpps

108Mpps/126Mpps

87Mpps/166Mpps

144Mpps/166Mpps

51Mpps/126Mpps

108Mpps/126Mpps

PoE

²»Ö§³Ö

²»Ö§³Ö

¹©µçÉè¼ÆÖ§³ÖIEEE 802.3af£¨15.4W£©¡¢IEEE 802.3at£¨30W£©

Ö§³Ö×Ô¶¯¡¢½ÚÄÜ¡¢¾²Ì¬¹©µçÖÎÀíģʽ

Ö§³Ö¶Ë¿ÚÓÅÏȼ¶

MACµØµã±í

Ö§³Ö¾²Ì¬MACµØµã

Ö§³ÖMACµØµã¹ýÂË

802.1Q VLAN

Ö§³Ö4K 802.1Q VLAN

Ö§³ÖPort based VLAN

Ö§³ÖMAC based VLAN

Ö§³ÖProtocol based VLAN

Ö§³ÖGVRP

¶þ²ã»·ÍøÊÖÒÕ

Ö§³ÖG.8032¹ú¼Ê±ê×¼»·ÍøÐ­ÒéERPS £¬£¬£¬£¬£¬£¬£¬¿ÉÓëÆäËûÖ§³Ö¸ÃЭÒéµÄ²úÆ·ÍêÉÆ¼æÈÝ

¶Ë¿Ú¾ÛºÏ

Ö§³ÖÁ÷Á¿Æ½ºâ·½·¨

Ö§³ÖLACP¶¯Ì¬¾ÛºÏ

Ö§³ÖLACPÓÅÏȼ¶/ЭÉÌ·½·¨¿ÉÉèÖÃ

DHCP

Ö§³ÖDHCP Server

Ö§³ÖDHCP Client

Ö§³ÖDHCP Snooping

Ö§³ÖDHCP Relay

IP·ÓÉ

¾²Ì¬Â·ÓÉ¡¢RIP¡¢RIPng¡¢*OSPFv2¡¢IPv6

ACL

Ö§³Ö±ê×¼IP ACL

Ö§³ÖÀ©Õ¹IP ACL£¨»ùÓÚIPµØµã¡¢TCP/UDP¶Ë¿ÚºÅµÄÓ²¼þACL£©

Ö§³ÖMACÀ©Õ¹ACL

Ö§³ÖACL80

Ö§³ÖÈ«¾ÖACL

Ö§³ÖACLÖØ¶¨Ïò

QoS

Ö§³Ö¶Ë¿ÚÏÞËÙ

Ö§³Ö802.1p/DSCPÁ÷Á¿·ÖÀà

ÿ¶Ë¿Ú8¸öÓÅÏȼ¶ÐÐÁÐ

Ö§³ÖSP¡¢WRR¡¢SP+WFQ¡¢SP+WRR¡¢RED/WREDÐÐÁе÷Àí

Çå¾²ÌØÕ÷

¹ýÂ˲»·¨µÄMACµØµã

Ö§³Ö¹ã²¥·ç±©¡¢¶à²¥·ç±©¡¢Î´×ÅÃûµ¥²¥ÒÖÖÆ

Ö§³ÖSSH

Ö§³ÖCPP

EEE

Ö§³ÖIEEE 802.3az ±ê×¼µÄ EEE½ÚÄÜÊÖÒÕ£ºµ±EEEʹÄÜʱ £¬£¬£¬£¬£¬£¬£¬´Ó¶ø´ó·ù¶ÈµÄ¼õС¶Ë¿ÚÔڸý׶εŦºÄ £¬£¬£¬£¬£¬£¬£¬µÖ´ïÁ˽ÚÄܵÄÄ¿µÄ¡£ ¡£¡£¡£ ¡£¡£¡£

ÖÎÀíÌØÕ÷

SNMP¡¢CLI(Telnet/Console)¡¢RMON¡¢SSH¡¢Syslog/Debug¡¢NTP/SNTP¡¢FTP¡¢TFTP¡¢Web

µçÔ´

½»Á÷£¨AC£©ÊäÈ룺
¶î¶¨µçѹ¹æÄ££º100V~240V
×î´óµçѹ¹æÄ££º90V~264V
ƵÂÊ£º50/60Hz

µçÉÈ

Ö§³ÖµçÉȵ÷ËÙ

¹¦ºÄ

≤28W

≤46W

Õû»ú¹¦ºÄ£¨²»´øPOE¸ºÔØ£©<42W

Õû»ú¹¦ºÄ£¨PoEÂúÔØ£©<432W

MTBF

£¾200K

ζÈ

ÊÂÇéζȣº0¡æ~50¡æ

´æ´¢Î¶ȣº-40¡æ~70¡æ

ʪ¶È

ÊÂÇéʪ¶È£º10%~90%RH

´æ´¢Êª¶È£º5%~95%RH

¶Ë¿Ú·ÀÀ×

6KV

*ÌåÏÖºóÐøÖ§³Ö

Õö¿ªÏêϸ²ÎÊý

Ó¦ÓôîÅä

ÍòÕ×ÍøÂç
ǧÕ×ÍøÂç
AGGAME¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
AGGAME¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾

³£¼ûÎÊÌâ

ÎÒÒªÌáÎÊ
ËùÓÐ
¶Ë¿ÚÐÝÃß(1)
¹©µç·½·¨(1)
PoE¹©µç(4)
µçÔ´(1)
½ÚÄÜ(1)
Èý²ã½»Á÷»ú(1)
»·Íø½»Á÷»ú(1)
¹âÄ£¿£¿£¿£¿£¿é(1)
ÊÊÓó¡¾°(1)
¹¦ÂÊ(2)
²úÆ·ÉèÖÃ(1)
aggame¹ÙÍø 2022Äê07ÔÂ25ÈÕ
RG-S2910V2-LϵÁо«¼òÐÍǧÕ×½»Á÷»úÊÇ·ñÊÇ»·Íø½»Á÷»ú£¿£¿£¿£¿£¿
ÓÐÓÃ 53 ÎÞÓÃ 8

ÊÇµÄ £¬£¬£¬£¬£¬£¬£¬ÎÒ˾֧³Ö“ERPSЭÒ锵Ľ»Á÷»ú¶¼ÊÇ»·Íø½»Á÷»ú £¬£¬£¬£¬£¬£¬£¬ÏêÇéÒ³ÃæÊÖÒÕ²ÎÊý°å¿éÒ²¿ÉÒԲ鵽´ËÐÅÏ¢¡£ ¡£¡£¡£ ¡£¡£¡£

aggame¹ÙÍø 2022Äê07ÔÂ25ÈÕ
RG-S2910V2-LϵÁо«¼òÐÍǧÕ×½»Á÷»úÖÐÓÐÖ§³ÖPoE¹©µçµÄÂ𣿣¿£¿£¿£¿
ÓÐÓÃ 41 ÎÞÓÃ 8

RG-S2910V2-24GT4SFP-P-L¡¢RG-S2910V2-24GT4XS-P-LÕâÁ½¿î24¸öµç¿ÚÖ§³ÖPoEºÍPoE+¹©µç£»£»£»£»£»£»Õû»ú×î´óPoE/PoE+Êä³ö¹¦ÂÊ£º370W £¬£¬£¬£¬£¬£¬£¬¹©µçÉè¼ÆÖ§³ÖIEEE 802.3af£¨15.4W£©¡¢IEEE 802.3at£¨30W£©¡£ ¡£¡£¡£ ¡£¡£¡£

Õö¿ªËùÓÐ
ÈôÊÇÄúÐèÒª¸ü¶à²úÆ·ÊÖÒÕ×Éѯ
ÏêϸÐÔÄÜÄÜ·ñÖª×ãÄúµÄÓªÒµ·åÖµ£¿£¿£¿£¿£¿ÔõÑùÍýÏë°²ÅÅÓëÉèÖã¿£¿£¿£¿£¿
Á¬Ã¦×Éѯ
AGGAME¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾

·µ»Ø¶¥²¿

ÊÕÆð
AGGAME¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾ ÎĵµAIÖúÊÖ
AGGAME¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾ ÎĵµÆÀ¼Û
¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌ⣿£¿£¿£¿£¿
Äú¶ÔÄ¿½ñÒ³ÃæµÄÖª×ã¶ÈÔõÑù£¿£¿£¿£¿£¿
²»Õ¦µÎ
ºÜÊǺÃ
ÄúÖª×ãµÄÔµ¹ÊÔ­ÓÉÊÇ£¨¶àÑ¡£ ¡£¡£¡£ ¡£¡£¡£©£¿£¿£¿£¿£¿
Äú¶ÔÎĵµÊÇ·ñÉÐÓÐÆäËüµÄÎÊÌâ»ò½¨Ò飿£¿£¿£¿£¿
Ϊ¾¡¿ì½â¾öÎÊÌâ £¬£¬£¬£¬£¬£¬£¬ÇëÄúÁôÏÂÁªÏµ·½·¨Òﱋȯ¸´
ÓÊÏä
ÊÖ»úºÅ
ллÄúµÄ·´Ïì£ ¡£¡£¡£ ¡£¡£¡£¡
AGGAME¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
AGGAME¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
AGGAME¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
ÇëÑ¡Ôñ·þÎñÏîÄ¿
¹Ø±Õ×Éѯҳ
ÊÛǰ×Éѯ ÊÛǰ×Éѯ
ÊÛǰ×Éѯ
ÊÛºó·þÎñ ÊÛºó·þÎñ
ÊÛºó·þÎñ
Òâ¼û·´Ïì Òâ¼û·´Ïì
Òâ¼û·´Ïì
¸ü¶àÁªÏµ·½·¨
¡¾ÍøÕ¾µØÍ¼¡¿¡¾sitemap¡¿