ÖÐÎÄ
ÆÕ±éÓ¦ÓÃÓÚÆÕ½Ì¡¢ÉÌÒµµØ²ú¡¢Ö°½Ì¡¢ÆóÒµµÈÊг¡£¡£¡£¡£¡£¡£¡£¬£¬£¬£¬£¬£¬£¬£¬Öª×ã°ì¹«Íø¡¢×°±¸ÍøµÈÓÃÍøÐèÇó
²úÆ·ÌØÕ÷£º




¿É½ÓÄÉWebÖÎÀí¡¢CLI(ÏÂÁîÐнӿÚ)µÈ¶àÑù»¯µÄÍâµØ»¯ÖÎÀíºÍά»¤·½·¨£¬£¬£¬£¬£¬£¬£¬£¬×°±¸ÖÎÀí¼òÆÓ±ã½Ý
Ö§³ÖSNMPÐÒ飬£¬£¬£¬£¬£¬£¬£¬¿É¶Ô½ÓµÚÈý·½ÍøÂçÖÎÀíÆ½Ì¨£¬£¬£¬£¬£¬£¬£¬£¬ÊµÏÖ¶Ô¶ą̀²î±ðÆ·ÅÆ×°±¸µÄͳһÖÎÀí£¬£¬£¬£¬£¬£¬£¬£¬ÍøÂçÔËάºÍÖÎÀí¸ü¸ßЧ
|
ÊÖÒÕ²ÎÊý |
||||||
|
²úÆ·ÐͺŠ|
RG-S2900-24GT4SFP/2GT-L |
RG-S2900-18GT2SFP-L |
RG-S2900-8GT2SFP-L |
RG-S2900-24GT4SFP/2GT-P-L |
RG-S2900-8GT2SFP-P-L |
|
|
Àο¿¶Ë¿Ú |
24¸ö10/100/1000M×Ô˳Ӧµç¿Ú£¬£¬£¬£¬£¬£¬£¬£¬4¸ö100M/1G SFP¹â¿Ú£¬£¬£¬£¬£¬£¬£¬£¬2¸ö¸´ÓõÄ10/100/1000M×Ô˳Ӧµç¿Ú |
18¸ö10/100/1000M×Ô˳Ӧµç¿Ú£¬£¬£¬£¬£¬£¬£¬£¬2¸ö100M/1G SFP¹â¿Ú |
8¸ö10/100/1000M×Ô˳Ӧµç¿Ú£¬£¬£¬£¬£¬£¬£¬£¬2¸ö100M/1G SFP¹â¿Ú |
24¸ö10/100/1000M×Ô˳Ӧµç¿Ú£¬£¬£¬£¬£¬£¬£¬£¬4¸ö100M/1G SFP¹â¿Ú£¬£¬£¬£¬£¬£¬£¬£¬2¸ö¸´ÓõÄ10/100/1000M×Ô˳Ӧµç¿Ú£¬£¬£¬£¬£¬£¬£¬£¬Ö§³ÖPoE/PoE+Ô¶³Ì¹©µç£¬£¬£¬£¬£¬£¬£¬£¬×î´ó¹©µç¹¦ÂÊ370W |
8¸ö10/100/1000M×Ô˳Ӧµç¿Ú£¬£¬£¬£¬£¬£¬£¬£¬2¸ö100M/1G SFP¹â¿Ú£¬£¬£¬£¬£¬£¬£¬£¬Ö§³ÖPoE/PoE+Ô¶³Ì¹©µç£¬£¬£¬£¬£¬£¬£¬£¬×î´ó¹©µç¹¦ÂÊ130W |
|
|
»ù±¾ÌØÕ÷ |
||||||
|
½»Á÷ÈÝÁ¿ |
336Gbps/3.36Tbps |
|||||
|
°üת·¢ÂÊ |
42Mpps/126Mpps |
42Mpps/96Mpps |
30Mpps/80Mpps |
42Mpps/126Mpps |
30Mpps/80Mpps |
|
|
¶þ²ãÌØÕ÷ |
||||||
|
MAC |
Ö§³Ö¹ýÂ˵صã Ö§³Ö¾²Ì¬µØµã Ö§³Ö8KµØµã±í |
|||||
|
802.1Q VLAN |
Ö§³Ö4K 802.1Q VLAN Ö§³ÖPort based VLAN |
|||||
|
AP |
Ö§³ÖÁ÷Á¿Æ½ºâ·½·¨¿ÉÉèÖà ֧³ÖLACP |
|||||
|
Çå¾²ÌØÕ÷ |
¹ýÂ˲»·¨µÄMACµØµã ÖÎÀíÔ±·Ö¼¶ÖÎÀíºÍ¿ÚÁî±£»£»£»£»£»£»£»¤ Ö§³ÖÓ²¼þCPP |
|||||
|
EEE |
Ö§³ÖIEEE 802.3az ±ê×¼µÄ EEE½ÚÄÜÊÖÒÕ£ºµ±EEEʹÄÜʱ£¬£¬£¬£¬£¬£¬£¬£¬´Ó¶ø´ó·ù¶ÈµÄ¼õС¶Ë¿ÚÔڸý׶εŦºÄ£¬£¬£¬£¬£¬£¬£¬£¬µÖ´ïÁ˽ÚÄܵÄÄ¿µÄ |
|||||
|
ÖÎÀíÌØÕ÷ |
SNMP¡¢CLI(Telnet/Console)¡¢Syslog/Debug¡¢NTP¡¢TFTP¡¢Web¡¢MACCŵ¿Í¹«ÓÐÔÆÆ½Ì¨ÖÎÀí |
|||||
|
ÎïÀíÌØÕ÷ |
|
|||||
|
µçÔ´ |
½»Á÷£¨AC£©ÊäÈ룺 |
|||||
|
×î´ó¹¦ºÄ |
RG-S2900-24GT4SFP/2GT-L£º≤22W RG-S2900-18GT2SFP-L£º≤17W RG-S2900-8GT2SFP-L£º≤8W RG-S2900-24GT4SFP/2GT-P-L£º≤430W£¨PoE£º370W£© RG-S2900-8GT2SFP-P-L£º≤145W£¨PoE£º125W£© |
|||||
|
PoE |
¹©µçÉè¼ÆÖ§³ÖIEEE 802.3afºÍ802.3atµÄ¹©µç±ê×¼ ×Ô´øÒ»¼üÉó²éPoE¹©µç״̬¹¦Ð§µÄPoE°´Å¥£¬£¬£¬£¬£¬£¬£¬£¬Çá°´¼´¿ÉÉó²é×°±¸Ä¿½ñµÄͨѶ״̬ºÍ¹©µç״̬£¬£¬£¬£¬£¬£¬£¬£¬¶Ô×°±¸ÏÖÔÚµÄÊÂÇé״̬һĿÁËÈ» Ö§³Ö»ùÓÚʱ¼äÕ½ÂÔ¶ÔPoE¶Ë¿Ú׼ʱÉÏϵç |
|||||
|
µçÉÈ |
ÎÞµçÉÈ£¬£¬£¬£¬£¬£¬£¬£¬×ÔȻɢÈÈ£¨³ý24¿ÚPoEÐͺţ© |
|||||
|
ÎÂ¶È |
ÊÂÇéζȣº-5¡æ~55¡æ ´æ´¢Î¶ȣº-40¡æ~70¡æ |
|||||
|
ʪ¶È |
ÊÂÇéʪ¶È£º10%~90%£¨·ÇÄý¾Û£© ´æ´¢Êª¶È£º5%~95%£¨·ÇÄý¾Û£© |
|||||
¸ÃϵÁн»Á÷»ú¶¼²»ÐèÒªµ¥ÅäµçÔ´£¬£¬£¬£¬£¬£¬£¬£¬³ýÁËRG-S2900-8GT2SFP-LÊÇÊÊÅäÆ÷¹©µç£¬£¬£¬£¬£¬£¬£¬£¬ÆäËûÐͺŶ¼Êǹ̻¯µ¥½»Á÷µçÔ´¡£¡£¡£¡£¡£¡£¡£
Ö§³Ö£¬£¬£¬£¬£¬£¬£¬£¬RG-2900-LϵÁн»Á÷»úÊÇÈ«Íø¹ÜÐÍ£¬£¬£¬£¬£¬£¬£¬£¬Ö§³ÖSNMP¡¢CLI(Telnet/Console)¡¢Syslog¡¢NTP¡¢TFTP¡¢WebµÈ£¬£¬£¬£¬£¬£¬£¬£¬ÍøÂçά»¤ÇáËɼòÆÓ¡£¡£¡£¡£¡£¡£¡£