RG-S5000-24GT4SFP
AGGAME¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
¼ÓÔØÖÐ...0%
ͼƬ

24¿ÚǧÕ×Èý²ãºÐʽ½ÓÈë²ã½»Á÷»ú £¬ £¬ £¬£¬£¬Ç§Õ×ÉÏÐÐ £¬ £¬ £¬£¬£¬RG-S5000-24GT4SFP

ÎªÔ°ÇøÍøÂç½ÓÈë×°±¸ÌṩǧÕ×µ½×ÀÃæµÄÓ¦Óà £¬ £¬ £¬£¬£¬Í¬Ê±Ìṩ´óÈÝÁ¿µÄǧÕ×ÉÏÐдø¿í £¬ £¬ £¬£¬£¬Öª×ã½ÓÈëÓû§ÐÅÏ¢Á¿ÈÕÒæÔöÌíµÄÐèÒª

²úÆ·ÌØÕ÷£º

  • 24¸ö10/100/1000Base-TÒÔÌ«Íø¿Ú
  • 4¸ö×ÔÁ¦Ç§Õ×SFP¹â¿Ú
  • Ö§³ÖVSUÐéÄ⻯ÊÖÒÕ £¬ £¬ £¬£¬£¬¼ò»¯ÍøÂçÖÎÀí
  • Ö§³ÖCPP/NFPP/RLDP/DHCP snooping¶àÖØÇå¾²·À»¤Õ½ÂÔ
  • ·çÀäÉ¢ÈÈ £¬ £¬ £¬£¬£¬ÖÇÄܵ÷ËÙ £¬ £¬ £¬£¬£¬µÍÔëÇÒ½ÚÄÜ
Á¬Ã¦×Éѯ

²úÆ·¸ÅÊö

RG-S5000ϵÁн»Á÷»úÊÇaggame¹ÙÍøÍøÂçÃæÏòÖÐÐ¡Ô°ÇøÍÆ³öµÄǧÕ×ÒÔÌ«Íø½»Á÷»ú¡£¡£¡£¡£¡£¡£¸ÃϵÁвúÆ·½ÓÄÉȫеÄÓ²¼þ¼Ü¹¹Éè¼Æ £¬ £¬ £¬£¬£¬´îÔØaggame¹ÙÍøÍøÂçRGOS11.XÄ £¿£¿£¿£¿£¿£¿ £¿£¿é»¯²Ù×÷ϵͳ £¬ £¬ £¬£¬£¬¿ÉÌṩ¸ü´óµÄ×ÊÔ´±íÏî¡¢¸ü¿ìµÄÓ²¼þ´¦Öóͷ£ÐÔÄÜ¡¢¸ü¸ßµÄ²Ù×÷ʹÓÃÌåÑé¡£¡£¡£¡£¡£¡£

RG-S5000ϵÁн»Á÷»úÎªÔ°ÇøÍøÂç½ÓÈë×°±¸ÌṩǧÕ×µ½×ÀÃæÓ¦Óà £¬ £¬ £¬£¬£¬Í¬Ê±Ìṩ´óÈÝÁ¿µÄǧÕ׺ÍÍòÕ×ÉÏÐдø¿í £¬ £¬ £¬£¬£¬Öª×ã½ÓÈëÓû§ÐÅÏ¢Á¿ÈÕÒæÔöÌíµÄÐèÒª¡£¡£¡£¡£¡£¡£

²úÆ·ÌØÕ÷

ÍêÉÆµÄÇå¾²·À»¤Õ½ÂÔ

×Ô¶¯·ÀÓùÍøÂçÖеÄÖÖÖÖDDoS¹¥»÷ £¬ £¬ £¬£¬£¬ÍøÂçÓÉÓÚÆä¿ª·ÅÐÔ £¬ £¬ £¬£¬£¬¾­³£ÓÉÓÚÅÌËã»úѬȾ²¡¶¾ £¬ £¬ £¬£¬£¬»òÊǽÓÈëÍøÂçµÄÖ°Ô±³öÓÚÖÖÖÖÄ¿µÄ¶ÔÍøÂç×°±¸¡¢ÍøÂçÖеķþÎñÆ÷¾ÙÐй¥»÷ £¬ £¬ £¬£¬£¬µ¼ÖÂÍøÂçÎÞ·¨Õý³£Ê¹Óᣡ£¡£¡£¡£¡£½Ï³£¼ûµÄÈçARP·ººé¹¥»÷µ¼ÖÂÍø¹ØÎÞ·¨ÏìÓ¦ÇëÇó¡¢ICMP·ººé¹¥»÷µ¼ÖÂÍøÂç×°±¸CPU¸ºÔعý¸ßÎÞ·¨Õý³£ÊÂÇé £¬ £¬ £¬£¬£¬DHCPÇëÇ󷺺鹥»÷ £¬ £¬ £¬£¬£¬µ¼ÖÂDHCP·þÎñÆ÷µØµã¿Ý½ß £¬ £¬ £¬£¬£¬Óû§ÎÞ·¨Õý³£»£»£» £»£»ñÈ¡IPµØµã»á¼ûÍøÂç¡£¡£¡£¡£¡£¡£

RG-S5000ϵÁÐÌṩÏȽøµÄÓ²¼þCPU±£»£»£» £»£»¤»úÖÆ£ºÌØÓеÄCPU±£»£»£» £»£»¤Õ½ÂÔ£¨CPP £¬ £¬ £¬£¬£¬CPU Protect Policy£© £¬ £¬ £¬£¬£¬¶Ô·¢ÍùCPUµÄÊý¾ÝÁ÷ £¬ £¬ £¬£¬£¬¾ÙÐÐÁ÷Çø·ÖºÍÓÅÏȼ¶ÐÐÁзּ¶´¦Öóͷ£ £¬ £¬ £¬£¬£¬²¢Æ¾Ö¤ÐèҪʵÑé´øÍÑÆÚËÙ £¬ £¬ £¬£¬£¬³ä·Ö±£»£»£» £»£»¤CPU²»±»²»·¨Á÷Á¿Õ¼ÓᢶñÒâ¹¥»÷ºÍ×ÊÔ´ÏûºÄ £¬ £¬ £¬£¬£¬°ü¹ÜÁËCPUÇå¾² £¬ £¬ £¬£¬£¬³ä·Ö±£»£»£» £»£»¤Á˽»Á÷»úµÄÇå¾²¡£¡£¡£¡£¡£¡£

RG-S5000ϵÁÐÌṩÏȽøµÄ»ù´¡ÍøÂç±£»£»£» £»£»¤Õ½ÂÔ£¨NFPP £¬ £¬ £¬£¬£¬Network Foundation Protection Policy£©ÊÖÒÕ £¬ £¬ £¬£¬£¬Äܹ»ÏÞÖÆÓû§ÏòÍøÂçÖз¢ËÍARP±¨ÎÄ¡¢ICMPÇëÇó±¨ÎÄ¡¢DHCPÇëÇó±¨ÎĵÈÊý¾Ý°üµÄÊýÂÊ £¬ £¬ £¬£¬£¬¶ÔÁè¼ÝÏÞËÙãÐÖµµÄ±¨ÎľÙÐÐÑïÆú´¦Öóͷ£ £¬ £¬ £¬£¬£¬ÉõÖÁÄܹ»Ê¶±ð¹¥»÷ÐÐΪ £¬ £¬ £¬£¬£¬¶ÔÓй¥»÷ÐÐΪµÄÓû§¾ÙÐиôÀë¡£¡£¡£¡£¡£¡£´Ó¶ø±£»£»£» £»£»¤»ù´¡ÍøÂçÃâÊÜÍøÂç¹¥»÷ÐÐΪµÄÓ°Ïì £¬ £¬ £¬£¬£¬°ü¹ÜÍøÂçÎȹ̡£¡£¡£¡£¡£¡£

Ö§³ÖDHCP snooping £¬ £¬ £¬£¬£¬¿ÉÖ»ÔÊÐíÐÅÍж˿ڵÄDHCPÏìÓ¦ £¬ £¬ £¬£¬£¬±ÜÃâ˽ÉèDHCP ServerµÄÓÕÆ­£»£»£» £»£»²¢ÔÚDHCP¼àÌýµÄ»ù´¡ÉÏ £¬ £¬ £¬£¬£¬Í¨¹ý¶¯Ì¬¼à²âARPºÍ¼ì²éÓû§µÄIP £¬ £¬ £¬£¬£¬Ö±½ÓÑïÆú²»Çкϰ󶨱íÏîµÄ²»·¨±¨ÎÄ £¬ £¬ £¬£¬£¬ÓÐÓÃÌá·ÀARPÓÕÆ­ºÍÓû§Ô´IPµØµãµÄÓÕÆ­ÎÊÌâ¡£¡£¡£¡£¡£¡£

ÐéÄâ½»Á÷µ¥Î»

RG-S5000ϵÁвúÆ·Ö§³ÖVSU£¨Virtual Switching Unit £¬ £¬ £¬£¬£¬ÐéÄâ½»Á÷µ¥Î»£© £¬ £¬ £¬£¬£¬Äܹ»½«¶ą̀ÎïÀí×°±¸¾ÙÐл¥Áª £¬ £¬ £¬£¬£¬Ê¹ÆäÐéÄâΪһ̨Âß¼­×°±¸ £¬ £¬ £¬£¬£¬Ê¹Óüòµ¥IPµØµã¡¢¼òµ¥TelnetÀú³Ì¡¢¼òµ¥ÏÂÁîÐнӿڡ¢×Ô¶¯°æ±¾¼ì²é¡¢×Ô¶¯ÉèÖõÈÌØÕ÷¾ÙÐÐÖÎÀí £¬ £¬ £¬£¬£¬¶ÔÓû§À´Ëµ½ö½öÊÇÔÚÖÎÀíһ̨װ±¸ £¬ £¬ £¬£¬£¬¿ÉÊÇȴʵÏÖ×Ŷą̀װ±¸´øÀ´µÄÊÂÇéЧÂʺÍʹÓÃÌåÑé¡£¡£¡£¡£¡£¡£

¼ò»¯ÖÎÀí£ºÖÎÀíÔ±¿ÉÒÔ¶Ô¶ą̀½»Á÷»úͳһÖÎÀí £¬ £¬ £¬£¬£¬¶ø²»ÐèÒªÅþÁ¬µ½Ã¿Ì¨½»Á÷»ú»®·Ö¾ÙÐÐÉèÖúÍÖÎÀí¡£¡£¡£¡£¡£¡£

¼ò»¯ÍøÂçÍØÆË£ºVSUÔÚÍøÂçÖÐÏ൱ÓÚһ̨½»Á÷»ú £¬ £¬ £¬£¬£¬Í¨¹ý¾ÛºÏÁ´Â·ºÍÍâΧװ±¸ÅþÁ¬ £¬ £¬ £¬£¬£¬²»±£´æ¶þ²ã»·Â· £¬ £¬ £¬£¬£¬Ã»ÐëÒªÉèÖÃMSTPЭÒé £¬ £¬ £¬£¬£¬ÖÖÖÖ¿ØÖÆÐ­ÒéÊÇ×÷Ϊһ̨½»Á÷»úÔËÐеġ£¡£¡£¡£¡£¡£

ºÁÃë¼¶¹ÊÕϻָ´£ºVSUºÍÍâΧװ±¸Í¨¹ý¾ÛºÏÁ´Â·ÅþÁ¬ £¬ £¬ £¬£¬£¬ÈôÊÇÆäÖÐһ̨װ±¸»òÕßÒ»Ìõ³ÉÔ±Á´Â··ºÆð¹ÊÕÏ £¬ £¬ £¬£¬£¬Çл»µ½ÁíÒ»Ìõ³ÉÔ±Á´Â·µÄʱ¼äÖ»ÐèÒªºÁÃë¼¶¡£¡£¡£¡£¡£¡£

¸ßÀ©Õ¹ÐÔ£ºÓû§ÐÂÔöµÄ×°±¸¼ÓÈë»òÍÑÀëÐéÄâ»¯ÍøÂçʱ¿ÉÒÔʵÏÖ¡°ÈȲå°Î¡± £¬ £¬ £¬£¬£¬²»Ó°ÏìÆäËû×°±¸µÄÕý³£ÔËÐС£¡£¡£¡£¡£¡£

±£»£»£» £»£»¤Í¶×Ê£ºVSUºÍÍâΧװ±¸Í¨¹ý¾ÛºÏÁ´Â·ÅþÁ¬ £¬ £¬ £¬£¬£¬¼ÈÌṩÁËÈßÓàÁ´Â· £¬ £¬ £¬£¬£¬ÓÖ¿ÉÒÔʵÏÖ¸ºÔØÆ½ºâ £¬ £¬ £¬£¬£¬³ä·ÖʹÓÃËùÓÐÍøÂç×°±¸ºÍ´ø¿í×ÊÔ´¡£¡£¡£¡£¡£¡£

¸ß¿É¿¿ÐÔ

¶àÀú³ÌÄ £¿£¿£¿£¿£¿£¿ £¿£¿é»¯²Ù×÷ϵͳRGOS 11.X £¬ £¬ £¬£¬£¬×é¼þ(Àú³Ì)Ï໥×ÔÁ¦ £¬ £¬ £¬£¬£¬Ò»¸ö×é¼þ(Àú³Ì)Í߽ⲻ»áÓ°Ïìµ½ÆäËû×é¼þ £¬ £¬ £¬£¬£¬Ö§³ÖÕë¶Ô¼òµ¥Ä £¿£¿£¿£¿£¿£¿ £¿£¿é´òÈȲ¹¶¡ £¬ £¬ £¬£¬£¬¹ÊÕÏÄ £¿£¿£¿£¿£¿£¿ £¿£¿éÉý¼¶Öв»Ó°ÏìÆäËûÀú³ÌµÄÕý³£ÔËÐкÍӪҵת·¢¡£¡£¡£¡£¡£¡£

Ö§³ÖÌìÉúÊ÷ЭÒé802.1D¡¢802.1w¡¢802.1s £¬ £¬ £¬£¬£¬°ü¹Ü¿ìËÙÊÕÁ² £¬ £¬ £¬£¬£¬Ìá¸ßÈÝ´íÄÜÁ¦ £¬ £¬ £¬£¬£¬°ü¹ÜÍøÂçµÄÎȹÌÔËÐкÍÁ´Â·µÄ¸ºÔØÆ½ºâ £¬ £¬ £¬£¬£¬ºÏÀíʹÓÃÍøÂçͨµÀ £¬ £¬ £¬£¬£¬ÌṩÈßÓàÁ´Â·Ê¹ÓÃÂÊ¡£¡£¡£¡£¡£¡£

Ö§³Ö¿ìËÙÁ´Â·¼ì²âЭÒ飨RLDP £¬ £¬ £¬£¬£¬Rapid Link Detection Protocol£© £¬ £¬ £¬£¬£¬¿É¿ìËÙ¼ì²âÁ´Â·µÄͨ¶ÏºÍ¹âÏËÁ´Â·µÄµ¥ÏòÐÔ £¬ £¬ £¬£¬£¬²¢Ö§³Ö¶Ë¿ÚÏµĻ·Â·¼ì²â¹¦Ð§ £¬ £¬ £¬£¬£¬±ÜÃâ¶Ë¿ÚÏÂÒò˽½ÓHubµÈ×°±¸ÐγɵĻ·Â·¶øµ¼ÖÂÍøÂç¹ÊÕϵÄÕ÷Ï󡣡£¡£¡£¡£¡£

Ö§³Ö¹«ÓÐÒÔÌ«Íø¶à»·±£»£»£» £»£»¤ÊÖÒÕ£¨ERPS£© £¬ £¬ £¬£¬£¬¹ú¼Ê±ê׼Ϊ½¹µãÒÔÌ«ÍøÉè¼ÆµÄ¶þ²ãÁ´Â·ÈßÓ౸·ÝЭÒé £¬ £¬ £¬£¬£¬Æä»·Â·×è¶ÏÒÔ¼°Á´Â·»Ö¸´¶¼¼¯ÖÐÔÚÖ÷¿Ø×°±¸ÉϾÙÐÐ £¬ £¬ £¬£¬£¬·ÇÖ÷¿Ø×°±¸Ö±½ÓÏòÖ÷¿Ø×°±¸»ã±¨×Ô¼ºµÄÁ´Â·ÇéÐÎ £¬ £¬ £¬£¬£¬ÎÞÐè¾­ÓÉÆäËû·ÇÖ÷¿Ø×°±¸µÄ´¦Öóͷ£ £¬ £¬ £¬£¬£¬Òò´Ë»·Â·ÖÐÖ¹ÒÔ¼°»Ö¸´Ê±¼ä±ÈSTP¿ì¡£¡£¡£¡£¡£¡£»£»£» £»£»ùÓÚÒÔÉÏÇø±ð £¬ £¬ £¬£¬£¬ERPSÔÚÀíÏëÇéÐÎϵÄÁ´Â·»Ö¸´ÄÜÁ¦Äܹ»µÖ´ïºÁÃë¼¶¡£¡£¡£¡£¡£¡£

Ö§³Ö¿ìËÙÒÔÌ«ÍøÉÏÁ´±£»£»£» £»£»¤Ð­Ò飨REUP £¬ £¬ £¬£¬£¬Rapid Ethernet Uplink Protection£© £¬ £¬ £¬£¬£¬ÔÚ²»ÆôÓÃSTPµÄÇéÐÎÏ £¬ £¬ £¬£¬£¬¿ÉÒÔÌṩһ¸ö¿ìËÙÉÏÁ´±£»£»£» £»£»¤¹¦Ð§ £¬ £¬ £¬£¬£¬REUPʹµÃÓû§ÔڹرÕSTPµÄÇéÐÎÏ £¬ £¬ £¬£¬£¬ÈÔÌṩ»ù±¾µÄÁ´Â·ÈßÓà £¬ £¬ £¬£¬£¬Í¬Ê±Ìṩ±ÈSTP¸ü¿ìµÄºÁÃë¼¶¹ÊÕϻָ´¡£¡£¡£¡£¡£¡£

ÂÌÉ«½ÚÄÜ

RG-S5000ϵÁн»Á÷»ú³ä·ÖÏìÓ¦¹ú¼ÒÂÌÉ«½ÚÄܵÄÕкô £¬ £¬ £¬£¬£¬½ÓÄɶàÖÖÂÌÉ«½ÚÄܵÄÉè¼ÆÀíÄî £¬ £¬ £¬£¬£¬Õë¶Ô¹Å°å½»Á÷»úÔÚÔëÒô¼°Äܺķ½Ãæ±£´æµÄÎÊÌâ¾ÙÐÐÉîÈëÑо¿Ì½Ë÷ £¬ £¬ £¬£¬£¬³ä·Ö½â¾öÁ˽»Á÷»ú°²ÅÅÔڰ칫ÇéÐÎÔëÉù´ó¡¢ÒÔ¼°½ÓÈë×°±¸´óÅúÁ¿°²Åźó´øÀ´µÄÄܺĹý´óµÄÎÊÌâ¡£¡£¡£¡£¡£¡£

RG-S5000ϵÁн»Á÷»ú½ÓÄÉÁËÐÂÒ»´úµÄÓ²¼þ¼Ü¹¹ÒÔ¼°ÏȽøµÄ½ÚÄܵç·Éè¼ÆºÍÔªÆ÷¼þÑ¡ÐÍ £¬ £¬ £¬£¬£¬ÎªÓû§½ÚÔ¼ÄÜºÄ £¬ £¬ £¬£¬£¬Í¬Ê±½µµÍÔëÒôÎÛȾ¡£¡£¡£¡£¡£¡£

RG-S5000Ö§³Ö¸ßЧ½ÚÄÜÒÔÌ«Íø£¨EEE£© £¬ £¬ £¬£¬£¬¶Ë¿ÚÈôÊÇÔÚÒ»Á¬Ò»¶Îʱ¼äÖ®ÄÚ¿ÕÏÐ £¬ £¬ £¬£¬£¬ÏµÍ³»á½«¸Ã¶Ë¿ÚÉèÖÃΪ½ÚÄÜģʽ £¬ £¬ £¬£¬£¬µ±Óб¨ÎÄÊÕ·¢Ê±ÔÙͨ¹ý׼ʱ·¢Ë͵ļàÌýÂëÁ÷½ÐÐѶ˿ڻָ´ÓªÒµ £¬ £¬ £¬£¬£¬µÖ´ï½ÚÄܵÄЧ¹û¡£¡£¡£¡£¡£¡£

RG-S5000ϵÁвúƷͬʱ֪×ãÖÊÁÏ»·±£ÓëÇå¾²ÐÔµÄÅ·ÃËRoHS±ê×¼¡£¡£¡£¡£¡£¡£

¼òÆÓÇáËɵÄÍøÂçά»¤

RG-S5000ϵÁÐÖ§³ÖÔÆÖÎÀí £¬ £¬ £¬£¬£¬¿ÉÒÔ´ø¸ø¿Í»§¼«¼òµÄÔËάÖÎÀíºÍÓû§ÌåÑé¡£¡£¡£¡£¡£¡£

Ò××éÍø£ºÖ»ÐèҪһ̨ÄÜÉÏÍøµÄPC»òÕßÊÖ»ú £¬ £¬ £¬£¬£¬¼´¿ÉÍê³É°²ÅÅ £¬ £¬ £¬£¬£¬¼´²å¼´Óᣡ£¡£¡£¡£¡£Ö§³Ö»ùÓÚÍø¹ØµÄÍøÂçÍØÆË×Ô¶¯·¢Ã÷ £¬ £¬ £¬£¬£¬²¢ÒÔͼÐλ¯ÐÎʽ·ºÆð

Ò×ÔËά£ºÔËά¼òÆÓ £¬ £¬ £¬£¬£¬ÍøÂçËæÊ±¿É¹Ü £¬ £¬ £¬£¬£¬ÈËÔÚÄÇÀïÍøÂç¾ÍÔÚÄÇÀï £¬ £¬ £¬£¬£¬ÓÐÏßÎÞÏßÍø¹Ø¾¡ÔÚÕÆÎÕÖС£¡£¡£¡£¡£¡£Ö§³ÖÉèÖÃÏ·¢¡¢ÉèÖñ¸·Ý¡¢ÉèÖûָ´¡¢ÏÂÁîµ÷ÊÔ¡¢»á¼ûeWeb¡¢»á¼ûTelnet¡¢»á¼ûSSH¡¢ÖØÆô¡¢×°±¸Éý¼¶

Ò×¼à¿Ø£º¿ÉËæÊ±Éó²éÍøÂ翵½¡¶È £¬ £¬ £¬£¬£¬×°±¸ÏêÇé(ϵͳ״̬¡¢Á÷Á¿×ßÊÆ¡¢Á¬Í¨ÐÔ¡¢¹©µç״̬µÈ) £¬ £¬ £¬£¬£¬¹ÊÕÏ¿ÉÊÓ £¬ £¬ £¬£¬£¬Óû§ÍøÂçÌåÑé¿ÉÊÓ £¬ £¬ £¬£¬£¬ÓÐ¸æ¾¯ÊµÊ±ÍÆËÍ £¬ £¬ £¬£¬£¬ÓÐÈÕÖ¾ÊÂÎñ¹©»ØËÝ¡£¡£¡£¡£¡£¡£Ö§³Ö¸æ¾¯¿Éͨ¹ý΢ÐŹ«Öںš¢Óʼþ¡¢Î¢ÐÅ¡¢ÆóÒµ¶¤¶¤·¢ËÍÌáÐÑ

Ò×ÈÏÖ¤£ºÒÀÍÐÔÆ¶Ë £¬ £¬ £¬£¬£¬ÕûÍø±ãÄÜÌṩÉÏÍøÊµÃûÈÏÖ¤ £¬ £¬ £¬£¬£¬²»±ØÈκεĸ½¼ÓÈí¼þºÍ·þÎñÆ÷¡£¡£¡£¡£¡£¡£

RG-S5000ϵÁÐÖ§³ÖSNMP¡¢RMON¡¢SyslogµÈÌØÕ÷À´¾ÙÐÐÍøÂçµÄÒ»Ñùƽ³£Õï¶Ï¼°Î¬»¤ £¬ £¬ £¬£¬£¬Í¬Ê±ÖÎÀíÔ±¿É½ÓÄÉCLI(ÏÂÁîÐнӿÚ)¡¢WebÍø¹Ü¡¢TelnetµÈ¶àÑù»¯µÄÖÎÀíºÍά»¤·½·¨¸üÀû±ã×°±¸µÄÖÎÀí¡£¡£¡£¡£¡£¡£?

Ö§³ÖSDN¿ØÖÆÆ÷ͳһÄÉ¹Ü £¬ £¬ £¬£¬£¬¼ò»¯ÍøÂçÖÎÀí £¬ £¬ £¬£¬£¬½µµÍÍøÂçά»¤±¾Ç®¡£¡£¡£¡£¡£¡£

PoEʹÓÃ״̬һĿÁËÈ»£ºÃæ°å×Ô´øÒ»¼üÉó²éPoE¹©µç״̬¹¦Ð§µÄPoE°´Å¥ £¬ £¬ £¬£¬£¬Çá°´¼´¿ÉÉó²é×°±¸Ä¿½ñµÄͨѶ״̬ºÍ¹©µç״̬ £¬ £¬ £¬£¬£¬ÈÃÄú¶ÔËùÓж˿ÚPoE¹©µçµÄ״̬ÁËÈ»ÓÚÐÄ¡£¡£¡£¡£¡£¡£

ÊÖÒÕ²ÎÊý

Ó²¼þ¹æ¸ñ

ϵͳ¹æ¸ñ

ϵͳ¹æ¸ñ RG-S5000-24GT4SFP RG-S5000-48GT4XS RG-S5000-24GT4XS RG-S5000-24GT4XS-P RG-S5000-24GT4SFP-P
½»Á÷ÈÝÁ¿ 672Gbps/6.72Tbps 672Gbps/6.72Tbps 672Gbps/6.72Tbps 672Gbps/6.72Tbps 672Gbps/6.72Tbps
°üת·¢ÂÊ 171Mpps 207Mpps 171Mpps 171Mpps 171Mpps
PoE¹©µç±ê×¼ ²»Ö§³Ö Ö§³ÖPoE/PoE+

½Ó¿ÚÓëÄ £¿£¿£¿£¿£¿£¿ £¿£¿é

½Ó¿ÚÓëÄ £¿£¿£¿£¿£¿£¿ £¿£¿é RG-S5000-24GT4SFP RG-S5000-48GT4XS RG-S5000-24GT4XS RG-S5000-24GT4XS-P RG-S5000-24GT4SFP-P
¹Ì»¯ÓªÒµ½Ó¿Ú 4¸ö1G SFP½Ó¿Ú 4¸ö10G/1G SFP+½Ó¿Ú 4¸ö10G/1G SFP+½Ó¿Ú 4¸ö10G/1G SFP+½Ó¿Ú 4¸ö1G SFP½Ó¿Ú
24¸ö10/100/1000Base-T×Ô˳ӦÒÔÌ«Íø½Ó¿Ú 48¸ö10/100/1000Base-T×Ô˳ӦÒÔÌ«Íø½Ó¿Ú 24¸ö10/100/1000Base-T×Ô˳ӦÒÔÌ«Íø½Ó¿Ú 24¸ö10/100/1000Base-T×Ô˳ӦÒÔÌ«Íø½Ó¿Ú 24¸ö10/100/1000Base-T×Ô˳ӦÒÔÌ«Íø½Ó¿Ú
¹Ì»¯ÖÎÀí½Ó¿Ú 1¸öRJ45 Console½Ó¿Ú
¹Ì»¯µçÔ´ÊýÄ¿ 1
¹Ì»¯µçÉÈÊýÄ¿ 1

µçÔ´Ó빦ºÄ

µçÔ´Ó빦ºÄ RG-S5000-24GT4SFP RG-S5000-48GT4XS RG-S5000-24GT4XS RG-S5000-24GT4XS-P RG-S5000-24GT4SFP-P
Õû»ú×î´ó¹¦ºÄ 24W 40W 24W 40W£¨²»´øPoE¸ºÔØ£© 40W£¨²»´øPoE¸ºÔØ£©
460W£¨PoEÂúÔØ£© 460W£¨PoEÂúÔØ£©
¶î¶¨ÊäÈëµçѹ¹æÄ£ 100Vac~240Vac,47~63Hz 100Vac~240Vac,47~63Hz 100Vac~240Vac,47~63Hz 100V AC~240V AC £¬ £¬ £¬£¬£¬50~60Hz
127V ~386Vdc 127V ~410Vdc 127V ~386Vdc 192V DC~290V DC
×î´óÊäÈëµçѹ¹æÄ£ 90V AC~264V AC £¬ £¬ £¬£¬£¬47~63Hz 90V AC~264V AC £¬ £¬ £¬£¬£¬47~63Hz 90V AC~264V AC £¬ £¬ £¬£¬£¬47~63Hz 90V AC~264V AC £¬ £¬ £¬£¬£¬50~60Hz
¶î¶¨ÊäÈëµçÁ÷ 0.6A 1.5A 0.6A 6.8A 6.8A

³ß´çÓëÖØÁ¿

³ß´çÓëÖØÁ¿ RG-S5000-24GT4SFP RG-S5000-48GT4XS RG-S5000-24GT4XS RG-S5000-24GT4XS-P RG-S5000-24GT4SFP-P
²úÆ·³ß´ç£¨¿í×Éî׸ߣ© 440mm x 220mm x 44mm
440mm x 220mm x 44mm
V2.XX°æ±¾£º440mm x 220mm x 43.6mm
ÖØÁ¿ 2.45kg 2.83kg 2.45kg 3.8kg 3.8kg
»ú¼Ü³ß´ç 1RU
×°Ö÷½·¨ ×ÀÃæ/±Ú¹Ò/»ú¼Ü£¨¹ñ£©

ÇéÐÎÓë¿É¿¿ÐÔ

ÇéÐÎÓë¿É¿¿ÐÔ RG-S5000-24GT4SFP RG-S5000-48GT4XS RG-S5000-24GT4XS RG-S5000-24GT4XS-P RG-S5000-24GT4SFP-P
ÏßÀÂÈȲå°Î Console¿Ú¡¢ÓªÒµ½Ó¿ÚÓëµçÔ´½Ó¿ÚÖ§³Ö
ÎÂ¶È ÊÂÇéζȣº0°C~50°C
´æ´¢Î¶ȣº-40°C~70°C
º£°Î1800~5000m£ºº£°ÎÿÉý¸ß100m £¬ £¬ £¬£¬£¬×î¸ßζȹæ¸ñ½µµÍ0.6¡æ
ʪ¶È ÊÂÇéʪ¶È£º10%RH~90%RH
´æ´¢Êª¶È£º5%RH~95%RH
ÔëÉù £¼45dBA £¼45dBA £¼45dBA £¼78dBA £¼78dBA
É¢ÈÈ ·çÀäÉ¢ÈÈ £¬ £¬ £¬£¬£¬ÓÒ½ø×ó³ö ·çÀäÉ¢ÈÈ £¬ £¬ £¬£¬£¬ÓÒ½ø×ó³ö ·çÀäÉ¢ÈÈ £¬ £¬ £¬£¬£¬ÓÒ½ø×ó³ö ·çÀäÉ¢ÈÈ £¬ £¬ £¬£¬£¬²à½øºó³ö ·çÀäÉ¢ÈÈ £¬ £¬ £¬£¬£¬²à½øºó³ö
ÎÂ¶È¼à¿Ø ÎÂ¶È¼à¿Ø£ºÖ§³Ö
ζȸ澯£ºÖ§³Ö
¹ýα£»£»£» £»£»¤£ºÖ§³Ö
µçÉÈ¼à¿Ø ²»Éæ¼° ¹ÊÕϸ澯£ºÖ§³Ö
ÊÖ¶¯µ÷ËÙ£º²»Ö§³Ö
ÖÇÄܵ÷ËÙ£ºÖ§³Ö
Ö§³ÖµçÉȵ÷ËÙ¼°µçÉȹÊÕϸ澯¹¦Ð§
µçÔ´¼à¿Ø ²»Éæ¼° Ä £¿£¿£¿£¿£¿£¿ £¿£¿é¼à¿Ø£º²»Ö§³Ö
¹ÊÕϸ澯£ºÖ§³Ö
ÖÇÄÜÉϵ磺²»Ö§³Ö
·ÀÀ× 10kV

Èí¼þ¹æ¸ñ

Èí¼þ¹æ¸ñ RG-S5000-24GT4SFP/ RG-S5000-24GT4XS RG-S5000-48GT4XS RG-S5000-24GT4SFP-P/ RG-S5000-24GT4XS-P
PoE ²»Ö§³Ö ²»Ö§³Ö ¹©µçÉè¼ÆÖ§³ÖIEEE 802.3af£¨15.4W£©¡¢IEEE 802.3at£¨30W£©
Ö§³Ö×Ô¶¯¡¢½ÚÄܹ©µçÖÎÀíģʽ
Ö§³ÖÈÈÆô¶¯²»ÖÐÖ¹¹©µç
Ö§³Ö¶Ë¿ÚÓÅÏȼ¶
Ö§³Ö¼æÈݷDZê×¼PD×°±¸
Ö§³Ö¶ÔPoE¶Ë¿Ú׼ʱÉÏϵç
MACµØµã±í Ö§³Ö¾²Ì¬MACµØµã
Ö§³ÖMACµØµã¹ýÂË
802.1Q VLAN Ö§³Ö4K 802.1Q VLAN
Ö§³ÖPort based VLAN
Ö§³ÖMAC based VLAN
Ö§³ÖProtocol based VLAN
Ö§³ÖPrivate VLAN
Ö§³ÖVoice VLAN
Ö§³ÖGVRP
QinQ Ö§³Ö»ù±¾QinQ
Ö§³ÖÎÞаQinQ
¶þ²ã»·ÍøÊÖÒÕ Ö§³ÖG.8032¹ú¼Ê±ê×¼»·ÍøÐ­ÒéERPS £¬ £¬ £¬£¬£¬Çл»Ê±¼ä≤200ms £¬ £¬ £¬£¬£¬¿ÉÓëÆäËûÖ§³Ö¸ÃЭÒéµÄ²úÆ·¼æÈÝ
¶Ë¿Ú¾ÛºÏ Ö§³ÖÁ÷Á¿Æ½ºâ·½·¨
Ö§³ÖLACP¶¯Ì¬¾ÛºÏ
Ö§³ÖLACPÓÅÏȼ¶/ЭÉÌ·½·¨ /×î´ó¿É¾ÛºÏ¿ÚÊýÄ¿ÉèÖÃ
Ö§³Ö¿çVSU AP
Mirror Ö§³ÖͨË×ÓªÒµ¿Ú¡¢¾ÛºÏ¶Ë¿Ú×÷Ϊ¾µÏñµÄÔ´ÒÔ¼°Ä¿µÄ¶Ë¿Ú
Ö§³Ö»ùÓÚÁ÷¡¢»ùÓÚVLANµÄÍâµØºÍÔ¶³Ì¾µÏñ
Ö§³ÖÒ»¶ÔÒ»¡¢¶à¶ÔÒ»¡¢Ò»¶Ô¶àµÄ¾µÏñ
Ö§³ÖRSPANºÍERSPAN
Ö§³Ö¿ç×°±¸µÄÁ÷Á¿¾µÏñ
DHCP Ö§³ÖDHCP Server
Ö§³ÖDHCP Client
Ö§³ÖDHCP Snooping
Ö§³ÖDHCP Relay
VSUÌØÕ÷ Ö§³ÖVSUÐéÄ⻯ÊÖÒÕ
IP·ÓÉ IPv4/IPv6¾²Ì¬Â·ÓÉ¡¢Ö§³ÖRIP¡¢RIPng¡¢OSPF¡¢OSPFv3ЭÒé
ACL Ö§³Ö±ê×¼IP ACL£¨»ùÓÚIPµØµãµÄÓ²¼þACL£©
Ö§³ÖÀ©Õ¹IP ACL£¨»ùÓÚIPµØµã¡¢TCP/UDP¶Ë¿ÚºÅµÄÓ²¼þACL£©
IP·ÓÉ Ö§³ÖMACÀ©Õ¹ACL£¨»ùÓÚÔ´MACµØµã¡¢Ä¿µÄMACµØµãºÍ¿ÉÑ¡µÄÒÔÌ«ÍøÀàÐ͵ÄÓ²¼þACL£©
ACL
QoS
Ö§³Ö»ùÓÚʱ¼äACL
Ö§³ÖACL80
Ö§³ÖÈ«¾ÖACL
Ö§³ÖACLÖØ¶¨Ïò
Ö§³Ö¶Ë¿ÚÁ÷Á¿Ê¶±ð
Ö§³Ö¶Ë¿ÚÁ÷Á¿ÏÞËÙ
Ö§³Ö802.1p/DSCP/TOSÁ÷Á¿·ÖÀà
QoS
Çå¾²ÌØÕ÷
ÿ¶Ë¿Ú8¸öÓÅÏȼ¶ÐÐÁÐ
Ö§³ÖSP¡¢WRR¡¢DRR¡¢SP+WFQ¡¢ SP+WRR¡¢SP+DRR¡¢RED/WREDÐÐÁе÷Àí
¹ýÂ˲»·¨µÄMACµØµã
Ö§³Ö¹ã²¥·ç±©ÒÖÖÆ
ÖÎÀíÔ±·Ö¼¶ÖÎÀíºÍ¿ÚÁî±£»£»£» £»£»¤
Çå¾²ÌØÕ÷
EEE
ÖÎÀíÌØÕ÷
Ö§³ÖRADIUS ºÍ TACACS+
Ö§³ÖSSH ºÍ SSH V2.0
Ö§³ÖBPDU Guard
Ö§³ÖCPP¡¢NFPP
Ö§³Ö¶Ë¿Ú±£»£»£» £»£»¤
Ö§³ÖIEEE 802.3az±ê×¼µÄEEE£¨Energy Efficient Ethernet £¬ £¬ £¬£¬£¬½ÚÄÜÒÔÌ«Íø£©ÊÖÒÕ
SNMP¡¢CLI(Telnet/Console)¡¢RMON¡¢SSH¡¢Syslog/Debug¡¢NTP/SNTP¡¢FTP¡¢TFTP¡¢Web¡¢WIS¹«ÓÐÔÆÆ½Ì¨ÖÎÀí
Õö¿ªÏêϸ²ÎÊý

³£¼ûÎÊÌâ

ÔÝÎÞÎÊÌâ £¬ £¬ £¬£¬£¬ÎÒÒªÌáÎÊ
ÈôÊÇÄúÐèÒª¸ü¶à²úÆ·ÊÖÒÕ×Éѯ
ÏêϸÐÔÄÜÄÜ·ñÖª×ãÄúµÄÓªÒµ·åÖµ £¿£¿£¿£¿£¿£¿ £¿£¿ÔõÑùÍýÏë°²ÅÅÓëÉèÖà £¿£¿£¿£¿£¿£¿ £¿£¿
Á¬Ã¦×Éѯ
AGGAME¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾

·µ»Ø¶¥²¿

ÊÕÆð
AGGAME¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾ ÎĵµAIÖúÊÖ
AGGAME¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾ ÎĵµÆÀ¼Û
¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌâ £¿£¿£¿£¿£¿£¿ £¿£¿
Äú¶ÔÄ¿½ñÒ³ÃæµÄÖª×ã¶ÈÔõÑù £¿£¿£¿£¿£¿£¿ £¿£¿
²»Õ¦µÎ
ºÜÊǺÃ
ÄúÖª×ãµÄÔµ¹ÊÔ­ÓÉÊÇ£¨¶àÑ¡£¡£¡£¡£¡£¡£© £¿£¿£¿£¿£¿£¿ £¿£¿
Äú¶ÔÎĵµÊÇ·ñÉÐÓÐÆäËüµÄÎÊÌâ»ò½¨Òé £¿£¿£¿£¿£¿£¿ £¿£¿
Ϊ¾¡¿ì½â¾öÎÊÌâ £¬ £¬ £¬£¬£¬ÇëÄúÁôÏÂÁªÏµ·½·¨Òﱋȯ¸´
ÓÊÏä
ÊÖ»úºÅ
ллÄúµÄ·´Ï죡£¡£¡£¡£¡£¡
AGGAME¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
AGGAME¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
AGGAME¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
ÇëÑ¡Ôñ·þÎñÏîÄ¿
¹Ø±Õ×Éѯҳ
ÊÛǰ×Éѯ ÊÛǰ×Éѯ
ÊÛǰ×Éѯ
ÊÛºó·þÎñ ÊÛºó·þÎñ
ÊÛºó·þÎñ
Òâ¼û·´Ïì Òâ¼û·´Ïì
Òâ¼û·´Ïì
¸ü¶àÁªÏµ·½·¨
¡¾ÍøÕ¾µØÍ¼¡¿¡¾sitemap¡¿