ÖÐÎÄ
ÔÆ¼Ü¹¹ÍøÂç½¹µã£¬£¬£¬£¬£¬£¬¸ß¼¶ÉèÖÃ
¸ßÐÔÄÜÖª×ãδÀ´Ê®ÄêÍøÂçÉú³¤
RG-S7800EϵÁÐÖ§³ÖÒµ½ç¸ßÐÔÄܵÄС°üÏßËÙת·¢ÄÜÁ¦£¬£¬£¬£¬£¬£¬°üÀ¨¸ßÃܶȰ忨ÔÚÄÚµÄËùÓа忨¾ù¿ÉʵÏÖ64×Ö½ÚС°üÏßËÙת·¢£¬£¬£¬£¬£¬£¬´ÓÈÝÓ¦¶ÔδÀ´ÍøÂç¶Ô¸ßËÙת·¢²»¶ª°üµÄ¿Á¿ÌÐèÇ󡣡£¡£¡£¡£¡£¡£¡£
ÐéÄ⻯ÈÃ×ÊÔ´°´Ðè·ÖÅÉ
ÐéÄâ½»Á÷µ¥Î»VSU3.0
RG- S7800EϵÁÐÖ§³ÖÒµ½ç³¬Ç°µÄVSU3.0£¨Virtual Switching Unit£¬£¬£¬£¬£¬£¬ÐéÄâ½»Á÷µ¥Î»£©ÐéÄ⻯ÊÖÒÕ£¬£¬£¬£¬£¬£¬½«¶ą̀ÎïÀí×°±¸ÐéÄ⻯Ϊһ̨Âß¼×°±¸£¬£¬£¬£¬£¬£¬Í³Ò»ÔËÐÐÖÎÀí£¬£¬£¬£¬£¬£¬´ó·ùïÔÌÍøÂç½Úµã£¬£¬£¬£¬£¬£¬½µµÍÍøÂçÔËάÖÎÀíÖ°Ô±ÊÂÇéÁ¿¡£¡£¡£¡£¡£¡£¡£¡£ÔöÌíÍøÂç¿É¿¿ ÐÔ£¬£¬£¬£¬£¬£¬ÊµÏÖ50~200msÁ´Â·¹ÊÕÏ¿ìËÙÇл»£¬£¬£¬£¬£¬£¬°ü¹ÜÒªº¦ÓªÒµ²»ÖÐÖ¹´«Êä¡£¡£¡£¡£¡£¡£¡£¡£Ö§³Ö¿ç×°±¸Á´Â·¾ÛºÏ£¬£¬£¬£¬£¬£¬Àû±ã½ÓÈë·þÎñÆ÷/½»Á÷»úʵÏÖË«»îÁ´Â·ÉÏÁª£¬£¬£¬£¬£¬£¬ÍøÂçÓÐÓÃÅþÁ¬´ø¿í³É ±¾ÔöÌí¡£¡£¡£¡£¡£¡£¡£¡£
ÐéÄâ½»Á÷×°±¸VSD
RG- S7800EϵÁÐͨ¹ýVSD£¨Virtual Switch Device£¬£¬£¬£¬£¬£¬ÐéÄâ½»Á÷×°±¸£©ÊÖÒտɽ«Ò»Ì¨×°±¸ÐéÄ⻯Ϊ¶ą̀ÐéÄâ×°±¸£¬£¬£¬£¬£¬£¬Ã¿Ì¨ÐéÄâ×°±¸¾ßÓÐ×ÔÁ¦µÄÉèÖÃÖÎÀí½çÃæ¡¢×ÔÁ¦Ó²¼þ×ÊÔ´·ÖÅÉ(ºÃ±ÈÄÚ´æ¡¢TCAM¡¢Ó²¼þ ת½ÒÏþ)£¬£¬£¬£¬£¬£¬¿ÉÒÔ×ÔÁ¦ÖØÆô¶ø²»Ó°ÏìÆäËüµÄÐéÄâ½»Á÷»ú¡£¡£¡£¡£¡£¡£¡£¡£ÓÐÓÃΪÄúʵÏÖÍøÂç×ÊÔ´µÄ°´Ðè·ÖÅÉ£¬£¬£¬£¬£¬£¬¿ÉÈý¹µã½»Á÷»ú×ÊԴͬʱ¹²Ïí¸ø¶à¸öÇøÓò»òÓû§Ê¹Óᣡ£¡£¡£¡£¡£¡£¡£
µçÐż¶µÄ¸ß¿É¿¿ÐÔÉè¼Æ
RG-S7800EϵÁи÷Òªº¦²¿¼þ¾ùΪÈßÓàÉè¼Æ£ºÖ÷¿ØÒýÇæ1+1ÈßÓ࣬£¬£¬£¬£¬£¬µçÉÈN+MÈßÓ࣬£¬£¬£¬£¬£¬µçÔ´Ä£¿£¿£¿£¿£¿£¿£¿£¿éN+MÈßÓ࣬£¬£¬£¬£¬£¬Í¬Ê±¸÷ÈßÓà×é¼þ¾ùÖ§³ÖÈȲå°Î£¬£¬£¬£¬£¬£¬ÓÐÓÃÌá¸ßÕû»úµÄ¿É¿¿ÐԺͿÉÓÃÐÔ¡£¡£¡£¡£¡£¡£¡£¡£
Ö§³ÖÈȲ¹¶¡ºÍISSUÊÖÒÕ£¬£¬£¬£¬£¬£¬¿ÉʵÏÖ×°±¸ÔÚÏß¾ÙÐв¹¶¡Éý¼¶¡£¡£¡£¡£¡£¡£¡£¡£
Ö§³ÖGR for OSPF/IS-IS/BGPµÈ£¬£¬£¬£¬£¬£¬Ö§³ÖBFD for VRRP/OSPF/BGP4/ISIS/ISISv6/MPLS/¾²Ì¬Â·Óɵȣ¬£¬£¬£¬£¬£¬ÊµÏÖ¸÷ÐÒéµÄ¿ìËÙ¹ÊÕϼì²â»úÖÆ£¬£¬£¬£¬£¬£¬¹ÊÕϼì²âʱ¼äСÓÚ50ms¡£¡£¡£¡£¡£¡£¡£¡£
¶àÀú³ÌÄ£¿£¿£¿£¿£¿£¿£¿£¿é»¯²Ù×÷ϵͳ
´Ó 1998ÄêÆð£¬£¬£¬£¬£¬£¬aggame¹ÙÍøÍøÂç¾Í×îÏÈÁËÄ£¿£¿£¿£¿£¿£¿£¿£¿é»¯²Ù×÷ϵͳµÄÑз¢Í¶È룬£¬£¬£¬£¬£¬RG-S7800EϵÁÐÈí¼þƽ̨»ùÓÚÐÂÒ»´úµÄRGOS 11.X¶àÀú³ÌÄ£¿£¿£¿£¿£¿£¿£¿£¿é»¯²Ù×÷ϵͳ£¬£¬£¬£¬£¬£¬½«ËÉñîºÏµÄ·À»ðǽ¡¢ÎÞÏß¡¢IPFIX¡¢ÈÏÖ¤µÈÓªÒµÌØÕ÷ºÏ²¢µ½Í³Ò»ÔƼܹ¹ÍøÂç²Ù×÷ϵͳƽ̨£¬£¬£¬£¬£¬£¬Ö§³ÖÐéÄ⻯ÄÜÁ¦ºÍ¸»ºñµÄÊý ¾ÝÖÐÐĺÍÔ°ÇøÍøÌØÕ÷¡£¡£¡£¡£¡£¡£¡£¡£ÔÚ¶àÀú³ÌÄ£¿£¿£¿£¿£¿£¿£¿£¿é»¯¡¢Àú³Ì±¸·Ý¡¢ÈȲ¹¶¡µÈÒªº¦¿ÉÓÃÐÔÖ¸±êÉϵִïÒµ½çÁìÏÈˮƽ¡£¡£¡£¡£¡£¡£¡£¡£
¸ßЧµÄÂÌÉ«½ÚÄÜ
RG-S7800EϵÁнÓÄÉ40nmоƬ¹¤ÒÕ£¬£¬£¬£¬£¬£¬Ïà±È¹Å°å90nmºÍ65nm¹¤ÒÕ¸ü½ÚÄÜ¡£¡£¡£¡£¡£¡£¡£¡£
ÄÚ²¿ÏµÍ³µÍѹ¹©µçÉè¼Æ£¬£¬£¬£¬£¬£¬¸ßЧÂÊÄ£¿£¿£¿£¿£¿£¿£¿£¿é»¯µçÔ´£¬£¬£¬£¬£¬£¬¹©µçϵͳЧÂʸü¸ß¡£¡£¡£¡£¡£¡£¡£¡£
¶àºËCPUÖ§³Ö¶¯Ì¬¹¦ºÄÖÎÀí£¬£¬£¬£¬£¬£¬ËùÓйâ¿Ú½ÓÄÉÎÞPHYÉè¼Æ£¬£¬£¬£¬£¬£¬½µµÍ¹â¿Ú¹¦ºÄ£¬£¬£¬£¬£¬£¬ËùÓÐÒÔÌ«Íøµç¿ÚÖ§³ÖEEE¸ßЧ½ÚÄܱê×¼£¬£¬£¬£¬£¬£¬µÍ¸ºÔØÊ±¿É½ÚÔ¼¹¦ºÄ¡£¡£¡£¡£¡£¡£¡£¡£
ÖÇÄܵçÉÈÖ§³Ö256¼¶µ÷ËÙ£¬£¬£¬£¬£¬£¬Ï¸ÃÜοأ¬£¬£¬£¬£¬£¬½ÚÄܽµÔ룻£»£»£»£»£»£»£»¸ßÎÂÏ¿ɺã¾ÃÊÂÇ飬£¬£¬£¬£¬£¬Ë³Ó¦±°ÁÓÇéÐΣ¬£¬£¬£¬£¬£¬ÎªÄú´ó·ù¶È½µµÍÄܺġ£¡£¡£¡£¡£¡£¡£¡£
|
ÊÖÒÕ²ÎÊý |
²ÎÊýÐÎò |
||
|---|---|---|---|
|
²úÆ·ÐͺŠ|
RG-S7805E |
RG-S7807E |
RG-S7810E |
|
Ä£¿£¿£¿£¿£¿£¿£¿£¿é²å²Û |
5¸ö£¨2¸öÓÃÓÚÖÎÀíÒýÇæÄ£¿£¿£¿£¿£¿£¿£¿£¿é£© |
7¸ö£¨2¸öÓÃÓÚÖÎÀíÒýÇæÄ£¿£¿£¿£¿£¿£¿£¿£¿é£© |
10¸ö£¨2¸öÓÃÓÚÖÎÀíÒýÇæÄ£¿£¿£¿£¿£¿£¿£¿£¿é£© |
|
½»Á÷ÈÝÁ¿ |
4.8Tbps/12Tbps |
8Tbps/20Tbps |
12.8Tbps/32Tbps |
|
°üת·¢ËÙÂÊ |
1,440Mpps/5,400Mpps |
2,400Mpps/9,000Mpps |
3,840Mpps/14,400Mpps |
|
×°±¸ÐéÄ⻯ |
Ö§³ÖVSU3.0(Virtual Switching Unit,ÐéÄâ½»Á÷µ¥Î») Ö§³ÖVSD(Virtual Switch Device,ÐéÄâ½»Á÷×°±¸) |
||
|
SDN |
Ö§³ÖOpenFlow 1.3 |
||
|
L2 ÌØÕ÷ |
Ö§³ÖJumbo Frame Ö§³Ö802.1Q Ö§³ÖSTP¡¢RSTP¡¢MSTP Ö§³ÖSuper VLAN Ö§³ÖGVRP Ö§³ÖQinQ¡¢ÎÞаQinQ¡¢QinQÖÕ½á Ö§³ÖLLDP |
||
|
IPv4 ÌØÕ÷ |
Ö§³Ö¾²Ì¬Â·ÓÉ¡¢RIP¡¢OSPF¡¢IS-IS¡¢BGP4 Ö§³ÖVRRP Ö§³ÖµÈ¼Û·ÓÉ Ö§³ÖÕ½ÂÔ·ÓÉ Ö§³ÖGREËíµÀ |
||
|
IPv6 ÌØÕ÷ |
Ö§³Ö¾²Ì¬Â·ÓÉ¡¢RIPng¡¢OSPFv3¡¢BGP4+¡¢IS-ISv6¡¢MLDv1/v2 Ö§³ÖVRRPv3 Ö§³ÖµÈ¼Û·ÓÉ Ö§³ÖÕ½ÂÔ·ÓÉ Ö§³ÖÊÖ¹¤ËíµÀ¡¢×Ô¶¯ËíµÀ¡¢ISATAPËíµÀ¡¢Ö§³ÖGREËíµÀµÈ |
||
|
×é²¥ |
Ö§³ÖIGMP v1,v2,v3 Ö§³ÖIGMP Snooping Ö§³ÖIGMP Proxy Ö§³ÖPIM-DM¡¢PIM-SM¡¢PIM-SSMµÈ×鲥·ÓÉÐÒé Ö§³ÖMLD Ö§³Ö×é²¥¾²Ì¬Â·ÓÉ |
||
|
MPLS |
Ö§³ÖMPLSת·¢ Ö§³ÖMPLS VPN/VPLS Ö§³ÖVPWS |
||
|
ACL |
Ö§³Ö±ê×¼¡¢À©Õ¹¡¢×¨¼Ò¼¶ACL Ö§³ÖACL 80 Ö§³ÖIPv6 ACL |
||
|
QoS |
Ö§³Ö802.1P Ö§³ÖSP¡¢WRR¡¢DRR¡¢SP+WRR¡¢SP+DRRµÈÐÐÁе÷Àí»úÖÆ Ö§³ÖRED/WRED Ö§³Ö»ùÓÚ³ö¶Ë¿Ú/Èë¶Ë¿ÚµÄÏÞËÙ Ö§³ÖHQoS |
||
|
PoE |
Ö§³ÖÉèÖÃPoEÏß¿¨£¬£¬£¬£¬£¬£¬²¢ÓÉ×ÔÁ¦PoEµçÔ´²Û¹©µç£¬£¬£¬£¬£¬£¬±ÜÃâÒòPoE¹©µç¶øÓ°ÏìÆäËûӪҵģ¿£¿£¿£¿£¿£¿£¿£¿é¹©µçÎȹÌÐÔ |
||
|
¿É¿¿ÐÔ |
×ÔÁ¦µÄ½»Á÷Íø°åÓë×ÔÁ¦µÄÖ÷¿Ø°åÉè¼Æ£¬£¬£¬£¬£¬£¬ÊµÏÖת·¢Óë¿ØÖÆÆ½ÃæÍêÈ«ÊèÉ¢ Ö÷¿Ø°åÖ§³Ö1+1ÈßÓ౸·Ý µçÔ´¡¢µçÉÈÖ§³ÖN+MÈßÓ౸·Ý ±³°åÎÞÔ´Éè¼Æ£¬£¬£¬£¬£¬£¬×èÖ¹µ¥µã¹ÊÕÏ ¸÷×é¼þÖ§³ÖÈȲå°Î Ö§³ÖÈȲ¹¶¡¹¦Ð§£¬£¬£¬£¬£¬£¬¿ÉÔÚÏß¾ÙÐв¹¶¡Éý¼¶ Ö§³ÖISSU Ö§³ÖGR for OSPF/IS-IS/BGP Ö§³ÖBFD for VRRP/OSPF/BGP4/ISIS/ISISv6/MPLS/¾²Ì¬Â·ÓÉµÈ |
||
|
Çå¾²ÐÔ |
Ö§³ÖNFPP£¨»ù´¡Çå¾²±£»£»£»£»£»£»£»£»¤Õ½ÂÔ£© Ö§³ÖCPP£¨CPU±£»£»£»£»£»£»£»£»¤£© Ö§³ÖDAI£¬£¬£¬£¬£¬£¬¶Ë¿ÚÇå¾²£¬£¬£¬£¬£¬£¬IP Source Guard Ö§³Ö802.1x/Portal/MacµÈ¶àÖÖÈÏÖ¤·½·¨ Ö§³ÖRADIUSºÍTACACS+Óû§µÇ¼ÈÏÖ¤ Ö§³ÖuRPF Ö§³ÖµÇ¼ÈÏÖ¤¡¢¿ÚÁîÇå¾² Ö§³Öδ֪×é²¥²»ËÍCPU¡¢Ö§³Öδ֪µ¥²¥ÒÖÖÆ Ö§³ÖSSHv2£¬£¬£¬£¬£¬£¬ÎªÓû§µÇ¼ÌṩÇå¾²¼ÓÃÜͨµÀ |
||
|
ÖÎÀíÐÔ |
Ö§³ÖConsole/AUX Modem/Telnet/SSH2.0 ÏÂÁîÐÐÉèÖà ֧³ÖFTP¡¢TFTP¡¢XmodemÎļþÉÏÏÂÔØÖÎÀí Ö§³ÖSNMP V1/V2c/V3 Ö§³ÖRMON Ö§³ÖNTPʱÖÓ Ö§³Ö¹ÊÕϺ󱨾¯ºÍ×Ô»Ö¸´ Ö§³ÖϵͳÊÂÇéÈÕÖ¾ Ö§³ÖsFLOWÁ÷Á¿ÆÊÎö |
||
|
³ß´ç£¨¿íxÉîx¸ß£©(mm) |
442 x 595 x 219.5(5U) |
442 x 595 x 352.8(8U) |
442 x 821 x 797.3(18U) |
|
µçÔ´ |
RG-PA1600I£º90~180V¹¦ÂÊ£º1200W£»£»£»£»£»£»£»£»180~264V¹¦ÂÊ£º1600W RG-PA600I£º90~180V¹¦ÂÊ£º600W£»£»£»£»£»£»£»£»180~264V¹¦ÂÊ£º600W RG-PD1600I£º-40.5V~ -75V¹¦ÂÊ£º1400W RG-PD600I£º-40.5V~ -75V¹¦ÂÊ£º600W RG-PA1600I-PL£º90~175V¹¦ÂÊ£º1000W£»£»£»£»£»£»£»£»176~264V¹¦ÂÊ£º1600W RG-PA3000I-PL£º90~175V¹¦ÂÊ£º2000W£»£»£»£»£»£»£»£»176~209V¹¦ÂÊ£º2500W£»£»£»£»£»£»£»£»210~264V¹¦ÂÊ£º3000W |
||
|
MTBF |
> 200,000 Сʱ |
||
|
ÎÂ¶È |
ÊÂÇéζȣº0¡æ µ½ 50¡æ ´æ´¢Î¶ȣº-40¡æ µ½ 70¡æ |
||
|
ʪ¶È |
ÊÂÇéʪ¶È£º10% µ½ 90% RH£¨ÎÞÀäÄý£© ´æ´¢Êª¶È£º5% µ½ 95% RH |
||
|
ÊÂÇé¸ß¶È/º£°Î |
-500~5000M |
||